Monophase Input (25 W -50 W) UP
Model

Power see data sheet

Output voltage (adjusted) Regulations EC ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
ML30.101
25 W

5 (5-5.5)

Regulations

OK OK OK ML30.101
45*75*91
Functions/Notes NEC Class II. Power Reserve 20-35%.
ML30.100
30 W

24 (24-28)

Regulations

OK OK OK ML30.100
45*75*91
Functions/Notes PULS Overload Design TM
ML30.102
30 W

12 (10-12)

Regulations

OK OK OK ML30_102
45*75*91
Functions/Notes Power Reserve 25-40%. Low ripple <2mVpp.
ML30.106
36 W

+/-12 or +/-15

Regulations

OK OK OK ML30.106
45*75*91
Functions/Notes PULS Overload Design TM
SL2.103
40 W

12 (12-15)

Regulations

OK OK OK SL2.103
49*124*102
Functions/Notes PULS Overload Design TM May be used in parallel
ML50.100
50 W

24 (24-28)

Regulations

OK OK OK ML50.100
45*75*91
Functions/Notes PULS Overload Design TM up to 1.5 times the rated current DC Ok signal.
ML50.101
50 W

24 (24-28)

Regulations

OK OK OK ML50.101
45*75*91
Functions/Notes PULS Overload Design TM up to 1.5 times the rated current DC Ok signal. .Permits parallel operation with current sharing..
ML50.102
50 W

12 (12-15)

Regulations

OK OK OK ML50.102
45*75*91
Functions/Notes NEC Class II. Power Reserve 10%.
ML50.105
50 W

48 (48-56)

Regulations

OK OK OK ML50.105
45*75*91
Functions/Notes NEC Class II. PULS Overload Design TM
ML50.111
50 W

24 (24-28)

Regulations

OK OK OK ML50.111
45*75*91
Functions/Notes NEC Class II. PULS Overload Design TM DC Ok signal. May be used in parallel
 
Monophase Input (60 W -100 W) UP
Model

Power see data sheet

Output voltage (adjusted) Regulations EC ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
SL2.100
60 W

24

Regulations

OK OK OK SL2.100
49*124*102
Functions/Notes NEC Class II. Power Reserve 20-35%.
SLR2.100
60 W

24

Regulations

OK OK OK SLR2.100
49*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. N+1 redundancy. NEC Class II. RDY relay.
ML30.100
72 W

24 (24-28)

Regulations

OK OK OK ML70.100
45*75*91
Functions/Notes NEC Class II. PULS Overload DesignTM.
QS3.241
80 W

24 (24-28)

Regulations

OK OK OK QS3.241
32*124*102
Functions/Notes PULS Overload DesignTM. Bonus Power 120 W. May be used in parallel. Redundancy Dimension
SLA3.100
85 W

30.5

Regulations

OK OK NO SLA3.100
49*125*103
Functions/Notes AS interface. IR addressing. NEC Class II.
ML100.102
90 W

12 (12-15)

Regulations

OK OK OK ML100.102
73*75*103
Functions/Notes May be used in parallel UL 1604.
QS5.DNET
91.2 W

24

Regulations

OK OK NO QS5.DNET
40*124*117
Functions/Notes Dimension. Device Net. NEC Class II.
ML95.100
95 W

24 (24-28)

Regulations

OK OK OK ML95.100
73*75*103
Functions/Notes NEC Class II. PULS Overload DesignTM. Permits parallel operation without current sharing.
SLA4.100
96 W

24

Regulations

OK OK NO SLA4.100
65*124*102
Functions/Notes NEC Class II. Parallel operation
ML100.100
100 W

24 (24-28)

Regulations

OK OK OK ML100.100
73*75*103
Functions/Notes PULS Overload DesignTM. May be used in parallel
ML100.105
100 W

48 (48-56)

Regulations

OK OK OK ML100.105
73*75*103
Functions/Notes PULS Overload DesignTM. May be used in parallel
 
Monophase Input (120 W -192 W) UP
Model

Power see data sheet

Output voltage (adjusted) Regulations EC ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
QS5.241
120 W

24 (24-28)

Regulations

OK OK NO QS5.241
40*124*117
Functions/Notes Bonus Power 180 W. PULS Overload DesignTM. May be used in parallel Redundancy Dimension.
SL5.100
120 W

24

Regulations

OK OK OK SL5.100
64*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 20%.
SL5.102
120 W

24 (24-28)

Regulations

OK OK OK SL5.102
64*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 20%.
SL5.105
120 W

24 (24-28)

Regulations

OK OK OK SL5.105
64*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 144 W. PFC
SLA4.100
120 W

30.5

Regulations

OK OK NO SLA4.100
73*124*102
Functions/Notes AS interface. IR addressing. Fuse Mode Earth failure detector.
SLR5.100
120 W

24

Regulations

OK OK OK SLR5.100
64*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. N+1 redundancy. NEC Class II. RDY relay.
QS10.121
180 W

12 (12-15)

Regulations

OK OK OK QS10.121
60*124*117
Functions/Notes Bonus Power 270 W. PULS Overload DesignTM. May be used in parallel Redundancy Dimension.
SL10.104
180 W

12 (12-15)

Regulations

OK OK OK SL10.104
120*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 144 W. PFC
QS10.DNET
192 W

24 (24-24.5)

Regulations

OK OK NO QS10.DNET
60*124*117
Functions/Notes Dimension. Device Net. NEC Class II.
 
Monophase Input (240 W) UP
Model

Power see data sheet

Output voltage (adjusted) Regulations EC ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
QS10.241
240 W

24 (24-28)

Regulations

OK OK OK QS10.241
60*124*117
Functions/Notes Bonus Power 360 W. PULS Overload DesignTM. May be used in parallel Redundancy Dimension.
QS10.301
240 W

30 (28-32)

Regulations

OK OK OK QS10.301
60*124*117
Functions/Notes Bonus Power 360 W. PULS Overload DesignTM. May be used in parallel Redundancy Dimension.
QS10.481
240 W

48 (48-56)

Regulations

OK OK OK QS10.481
60*124*117
Functions/Notes Bonus Power 360 W. PULS Overload DesignTM. May be used in parallel Redundancy Dimension.
SL10.100
240 W

24 (24-28)

Regulations

OK OK OK SL10.100
120*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 288 W.
SL10.101
240 W

48 (48-56)

Regulations

OK OK OK SL10.101
120*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 288 W.
SL10.105
240 W

24 (24-28)

Regulations

OK OK OK SL10.105
120*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 288 W. PFC
SL10.106
240 W

48 (48-56)

Regulations

OK OK OK SL10.106
120*124*102
Functions/Notes PULS Overload DesignTM.PowerBoost 288 W.Can be used in parallel. PFC
SLA8.100
240 W

30.5

Regulations

OK OK NO SLA8.100
91*124*101
Functions/Notes AS interface. IR Routing Fuse Mode
SLR10.100
240 W

24

Regulations

OK OK OK SLR10.100
120*124*102
Functions/Notes PULS Overload DesignTM. .Permits parallel operation with current sharing.. PowerBoost 288 W. N+1 Redundancy. RDY Relay.
 
Monophase Input (480 W -720 W) UP
Model

Power see data sheet

Output voltage (adjusted) Regulations EC ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
SL20.100
480 W

24 (24-28)

Regulations

OK OK OK SL20.100
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W.
SL20.101
480 W

24 (24-28)

Regulations

OK OK OK SL20.101
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W. PFC
SL20.110
480 W

24 (24-28)

Regulations

OK OK OK SL20.110
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W. Selectable overload response.
SL20.111
480 W

24 (24-28)

Regulations

OK OK OK SL20.111
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W. Selectable shared overload feature . PFC
SL20.112
480 W

36 (36-43)

Regulations

OK OK NO SL20.112
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units.
SL20.113
480 W

48 (48-56)

Regulations

OK OK OK SL20.113
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W.
SL20.115
480 W

24 (24-28)

Regulations

OK OK OK SL20.115
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 10 units. PowerBoost 600 W. Selectable shared overload feature . PFC
SL10.105
720 W

24 (24-28)

Regulations

OK OK OK SL30.100
220*124*102
Functions/Notes PULS Overload DesignTM. Permits parallel operation with current sharing. up to 5 units.

Information: check the PDF for each model to determine the real output power, temperature range, parallel use possibilities, or any other important detail. If you have any doubts, contact us

All PULS models have been designed to withstand alternating current input peaks of up to 750V for 1.3 milliseconds, as per VDE 0160.

You will need Adobe Acrobat Reader to view the files.

[Back]

[Power supplies and converters home] [Search for power supplies and converters]
[Mean Well power supplies and convertersl] [Puls power supplies and converters]
[Inverters]

 

P. Ind. Casablanca II. Avda. Severo Ochoa, 37 28100 Alcobendas - MADRID
Telf: +34 914840850 info@olfer.com
C/ Fabra i Puig 480, local 4. 08042 BARCELONA
Telf: +34 932749082 bcnolfer@olfer.com