Electrónica Olfer Home | Company | Produts | What's new? | Articles | Contact  
Electronic Components Distributor
Fuentes de alimentación
Power Supplies
PRODUCTS
 
 
Search for
Power Supplies / Converters

1.2)Open Type - Double Output
           
Go to power 25-200W
 
Double Output (25 W -200 W) UP
Series

Power see data sheet

Output voltage Regulations CE ROHS Normal Stock
Image
Dimensions
L*W*H(mm)
PD -25
25 W 5 and 12,
5 and 24,
5 and -5,
12 and -12,
15 and -15,
3.3 and 5

Certifications

OK OK OK PD-25
107*61*28
PD -45
45 W 5, 12, 5 and 24.

Certifications

OK OK OK PD-45
127*76*28
MPD-45
45 W 5, 12, 5 and 24.

Certifications

OK OK NO
MPD-45
127*76*28
Functions/Notes Medical and industrial.
RPD-60
60 W 5, 12, 5 and 24.

Certifications

OK OK NO
RPD-60
101.6*50.8*29
Functions/Notes Medical and industrial.
PD -65
65 W 5, 12, 5 and 24.

Certifications

OK OK OK PD-65
127*76*42
RPD-65
65 W 5, 12, 5 and 24.

Certifications

OK OK NO
RPD-65
127*76*28
(no case)
Functions/Notes Optional case
MPD-65
65 W 5, 12, 5 and 24.

Certifications

OK OK NO
MPD-65
127*76*42
Functions/Notes Medical and industrial.
PD -110
110 W 5, 12, 5 and 24.

Certifications

OK OK NO
PD-110
177.8*107.95*46
Functions/Notes This series will be replaced by MPD-120
MPD-120
120 W 5, 12, 5 and 24.

Certifications

OK OK NO
MPD-120
177.8x107.95x35.5
Functions/Notes Medical and industrial.
MPD-200
200 W 5, 12, 5 and 24.

Certifications

OK OK NO
MPD-200
177.8x107.2x35.5
Functions/Notes Medical and industrial.

Information: check the PDF for each model to determine the real output power, temperature range, parallel use possibilities, or any other important detail. If you have any doubts, contact us

Important:Most multiple output power supplies require a minimum load to function as per the specifications. If the minimum specified load is not used then the output voltages may suffer fluctuations greater than those specified, or the device may not switch on. If you have any doubts, contact us

Models with several outputs indicate a current range (amps) for each output. Nevertheless, we may never exceed the maximum power for the device. For example, the D-60A model has Double Output: 5 and 12 VDC. The 5Vdc output indicates a range of 0.3 (minimum load) to 6 amps, and the output of 12VDC from 0.2 to 4 amps. If we calculate the maximum power per output:

5VDC 6 amps = 30 W and 12VDC to 4 amps = 48 W
This calculation could lead to incorrect conclusions as it assumes that we may receive the maximum power from both outputs at the same time.The sum of the maximum power from both outputs is 78W, but the maximum power output for this model is 56W, thus forcing us to share the load as required (complying with the minimum load requirements) without exceeding the maximum power output (56 W).

You will need Adobe Acrobat Reader to view the files.

[Back]

[Power supplies and converters home] [Search for power supplies and converters]
[Mean Well power supplies and converters] [Puls power supplies and converters]
[Inverters]

 

P. Ind. Casablanca II. Avda. Severo Ochoa, 37 28100 Alcobendas - MADRID
Telf: +34 914840850 info@olfer.com
C/ Fabra i Puig 480, local 4. 08042 BARCELONA
Telf: +34 932749082 bcnolfer@olfer.com